Intended Use
General Description
The SD/SDV-Series screwdriver tools are intended for use as end-of-arm tooling on industrial robots in automated screwdriving applications.
Screwdriving applications are defined as fastening operations using:
Threaded fasteners
Self-cutting screws
Thread-forming screws
The tool is designed to be integrated into a complete robot system.
Important
The SD/SDV tool is not a standalone machine and must only be used as part of a properly designed and validated robot application.
Operating Conditions
The tool is intended for operation under the following conditions:
Indoor use only
Dry environment (non-condensing)
Ambient temperature: 0–50°C
Relative humidity: max. 85%
Maximum operating altitude: 2000 m
Warning
Operation outside these conditions may result in malfunction, reduced performance, or unsafe operation.
Intended Application Scope
The SD/SDV-Series is specifically designed for:
Automated screwdriving processes
Controlled fastening operations
Use with compatible screw bits and accessories
Note
The tool must be used in accordance with the specifications, instructions, and limitations described in this manual.
Reasonably Foreseeable Misuse
Any use outside the intended use is considered misuse.
Examples include, but are not limited to:
Use in explosive or flammable atmospheres (ATEX)
Use in medical or life-critical applications
Use without performing a risk assessment
Use without proper training of operators and personnel
Use outside specified environmental or operational conditions
Prohibited Use
The following uses are strictly prohibited:
Use near human head, face, or eye area
Use for processes other than screwdriving (e.g. polishing, grinding, deburring)
Use as a press, pry bar, drill, cutter, or hammer
Manual guiding outside intended collaborative operation
Operation without required safety functions enabled
Performing maintenance or tool changes with power applied (no lockout/tagout)
Cleaning with high-pressure water, steam, or incompatible chemicals
Use with incorrect or damaged electrical or pneumatic connections
Warning
Misuse may result in:
Injury to personnel
Damage to equipment
Loss of process control
Integrator Responsibility
The integrator is responsible for ensuring that:
The application is within the intended use
A complete risk assessment is performed
The system is installed and operated safely
All operators are properly instructed
Important
Safe operation of the SD/SDV-Series depends on correct system integration, proper programming, and compliance with applicable safety standards.