SD/SDV-Series
Note
SD and SDV variants share identical technical specifications.
Model Overview
Model |
Torque (Nm) |
Speed (rpm) |
Screw size |
Weight |
|---|---|---|---|---|
SD/SDV35 |
0.3 – 3.3 |
15 – 730 |
M2.5 – M5 |
2.4 kg |
SD/SDV50 |
0.5 – 5.0 |
15 – 510 |
M2.5 – M5 |
2.4 kg |
SD/SDV70 |
0.8 – 7.0 |
15 – 350 |
M3 – M6 |
2.4 kg |
SD/SDV120 |
2.0 – 12.0 |
15 – 180 |
M5 – M8 |
2.5 kg |
Note
The specified screw capacity is indicative and reflects typical screw sizes within the defined torque range of each tool.
Smaller or larger screws may be used depending on the application, material, and process conditions.
For example:
SD/SDV120 can be used for smaller screws (e.g. M4)
SD/SDV35 and SD/SDV50 can be used for larger screws (e.g. M6)
Final tool selection should always be based on the required torque and application conditions.
Model-Specific Specifications
Parameter |
SD/SDV35 |
SD/SDV50 |
SD/SDV70 |
SD/SDV120 |
|---|---|---|---|---|
Torque range (Nm) |
0.3 – 3.3 |
0.5 – 5.0 |
0.8 – 7.0 |
2.0 – 12.0 |
Torque accuracy |
±10 % |
±10 % |
±10 % |
±10 % |
Speed (rpm) |
15 – 730 |
15 – 510 |
15 – 350 |
15 – 180 |
Screw capacity |
M2.5 – M5 |
M2.5 – M5 |
M3 – M6 |
M5 – M8 |
Mechanical
Parameter |
Value |
|---|---|
Dimensions |
52 × 325 × 159 mm |
Safety shield diameter |
Ø15 mm |
Max screw length (safe) |
35 mm |
Supported screw types |
Machine, self-cutting, self-forming |
Robot interface |
ISO 9409-1 (50-4-M6) |
Electrical
Parameter |
Value |
|---|---|
Power (from SpinBridge) |
42–54 V DC @10A |
Motor power |
70 W (continuous) |
Electrical interface |
8-pin M12 (signal) 4-pin M12 (power) |
Note
All electrical power for the tool is supplied by the SpinBridge. See Electrical Interfaces for system integration.
Environmental
Parameter |
Value |
|---|---|
Temperature range |
0 – 50 °C |
IP classification |
IP53 |
ESD safe |
Yes |
Vacuum Interface (SDV only)
Parameter |
Value |
|---|---|
Connection type |
Push-in |
Tube size |
6 mm (OD) |
Thread |
M5 |
Minimum vacuum level |
≥ 60 % (−0.6 bar) |
Vacuum type |
Continuous |
Note
Vacuum must be supplied externally by the integrator.
Note
The system is not fully sealed. Continuous vacuum is required.